Photo collage containing images of Austin Water employees, construction workers, and water infrastructure including pipes and treatment facilities.

Backflow Prevention Assembly Tester Information

Notice for Water Service Technicians

With the WEIRS retirement, the new Klir application is now live for entering Austin Water’s Water Protection test submissions. Please bookmark the Klir Technician Portal link https://austinwater.klirportal.com/.

Note: Testers that previously had a WEIRS account should have received a registration email from the Klir system. Follow the instructions in that message to create your new login.

Klir Training Materials:

To test backflow prevention assemblies in the Austin Water distribution area, Backflow Prevention Assembly Testers (BPATs) must be licensed by the Texas Commission on Environmental Quality (TCEQ) and registered with Austin Water. BPATs play an important role in protecting the public water supply by testing and repairing backflow prevention assemblies.

For more information, contact the Utility Compliance Services Division’s Water Protection team by email at awcrossconnection@austintexas.gov or via phone at 512-972-1060, option 5 then option 1.

Testing Standards

Backflow prevention assemblies must be tested for operational effectiveness using methods approved by the TCEQ and described in the University of Southern California's Cross Connection Manual (USC-CCM). Each BPAT must use equipment calibrated by an approved gauge testing company within acceptable tolerances specified by the USC-CCM.

BPATs must comply with all applicable TCEQ licensing and certification requirements. Enforcement of state licensing requirements is the responsibility of the appropriate state agency.

Test and Maintenance Reports

Each BPAT must submit a complete and legible Test and Maintenance Report (TMR) to Austin Water for each assembly tested on the same day of the test. All TMRs must be submitted online through the Klir Technician Portal - paper copies are no longer accepted.

Each TMR must include:

  • BPA physical address and location on the premises
  • Cause requiring backflow protection
  • BPA manufacturer, size, model number and serial number
  • BPA operational test results
  • Description of repairs, if applicable, and retest results after repairs
  • Name of owner or occupant responsible for the BPA
  • Name of owner's representative
  • Owner's complete mailing address
  • BPAT printed name, signature and license number
  • Test gauge serial number
  • Date of operational test

Illegal Installations

Each BPAT must document any illegal or unapproved BPA installations or unprotected potential backflow or cross-connection sources and submit that documentation to Austin Water.

BPA or Hazard Removal

When a BPA is removed, the BPAT must submit a TMR to Austin Water indicating the assembly has been removed or replaced. If the hazard has not been eliminated, the BPA must be replaced to maintain uninterrupted backflow prevention. If the hazard is eliminated, the BPA may remain in place, but the elimination must be reported to the Utility Compliance Services Division so the assembly's out-of-service status can be recorded in the Klir Technician Portal and testing requirements removed.

Compliance and Enforcement

Austin Water reviews records and conducts investigations to determine compliance with applicable rules. Falsifying records submitted to Austin Water will result in criminal prosecution. Falsification includes:

  • Submitting a TMR without actually conducting the operational test
  • Intentionally submitting inaccurate testing results
  • Submitting a name, signature or certification number other than that of the person who performed the test
  • Testing a BPA before installation and submitting the TMR as if the test occurred after installation
  • Using a test gauge that does not meet calibration specifications
  • Using unapproved or unregistered testing equipment

Other violations may result in a Notice of Violation or other administrative enforcement response. BPATs who receive three notices of violation within a two-year period will have their City of Austin registration suspended for one year.

BPAT Registration

In-person registrations are no longer accepted. 

Obtaining a TCEQ License

To receive a TCEQ BPAT license, applicants must complete a 40-hour TCEQ-accredited backflow prevention course, pass the TCEQ license exam and pay the applicable fee. See TCEQ Occupational Licenses: Backflow Prevention Assembly Tester for details.

Registering with Austin Water

After receiving a TCEQ license, complete a Tester Registration Form. Please ensure the email address and cell phone number on the Registration Form are unique to you (not shared).

Once the Utility Compliance Services Division Water Protection team has processed the Registration Form, you will receive a Klir Portal invite to the email address provided on the Registration Form. Upon receiving the Klir Portal invite, you will be able to:

  • Create a Klir Portal account.
  • Submit your TCEQ BPAT license information (in Klir).
  • Submit information for any personal gauges to be used (in Klir).
  • Submit a copy of your driver’s license/passport (in Klir).

After Registration

Once Austin Water has reviewed and approved the license and gauge information, tests can be entered in Klir. You can also refer to the “Forms and Resources” section below for Klir training materials. 

Renewing Your Registration

To renew a TCEQ BPAT license, complete 24 hours of TCEQ-accredited continuing education, including eight hours of practical skills. After completion, testers can submit a license renewal request in Klir.

Approved Backflow Gauge Testing Companies

Calibration of backflow test kits is required to ensure they are functioning properly. The following companies provide approved calibration services in the Austin area:

CompanyAddressPhone
Fluid Meter Service Corp7304 McNeil Drive, Suite 604, Austin, TX 78729512-258-3594
Test Gauge and Backflow Supply3321 Garden Brook Drive, Farmers Branch, TX 75234469-206-3741

To add your company to this list, email your company name, address and phone number to awcrossconnection@austintexas.gov.

Forms and Resources

Forms

Lists

Other Resources